= Infinispan default XML configuration location
Previous releases ignored any change to `conf/cache-ispn.xml` if the `--cache-config-file` option was not provided.
Starting from this release, when `--cache-config-file` is not set, the default Infinispan XML configuration file is `conf/cache-ispn.xml` as this is both the expected behavior and the implied behavior given the docs of the current and previous releases.
= Embedded Infinispan: `work` cache must be replicated
The embedded `work` cache needs to be configured as a `replicated-cache` for cache invalidation to work as expected.
Starting from this release, {project_name} check this at startup and will fail to start if it is not configured as such.